691 research outputs found

    Multi-contrast Photoacoustic Microscopy

    Get PDF
    Photoacoustic microscopy is a hybrid imaging modality with high spatial resolution, moderate imaging depth, excellent imaging contrast and functional imaging capability. Taking full advantage of this powerful weapon, we have investigated different anatomical, functional, flow dynamic and metabolic parameter measurements using photoacoustic microscopy. Specifically, Evans-blue dye was used to enhance photoacoustic microscopy of capillaries; label-free transverse and axial blood flow was measured based on bandwidth broadening and time shift of the photoacoustic signals; metabolic rate of oxygen was quantified in vivo from all the five parameters measured by photoacoustic microcopy; whole cross-sectional imaging of small intestine was achieved on a double-illumination photoacoustic microscopy with extended depth of focus and imaging depth; hemodynamic imaging was performed on a MEMS-mirror enhanced photoacoustic microscopy with a cross-sectional imaging rate of 400 Hz. As a maturing imaging technique, PAM is expected to find new applications in both fundamental life science and clinical practice

    Photoacoustic microscopy

    Get PDF
    Photoacoustic microscopy (PAM) is a hybrid in vivo imaging technique that acoustically detects optical contrast via the photoacoustic effect. Unlike pure optical microscopic techniques, PAM takes advantage of the weak acoustic scattering in tissue and thus breaks through the optical diffusion limit (∼1 mm in soft tissue). With its excellent scalability, PAM can provide high-resolution images at desired maximum imaging depths up to a few millimeters. Compared with backscattering-based confocal microscopy and optical coherence tomography, PAM provides absorption contrast instead of scattering contrast. Furthermore, PAM can image more molecules, endogenous or exogenous, at their absorbing wavelengths than fluorescence-based methods, such as wide-field, confocal, and multi-photon microscopy. Most importantly, PAM can simultaneously image anatomical, functional, molecular, flow dynamic and metabolic contrasts in vivo. Focusing on state-of-the-art developments in PAM, this Review discusses the key features of PAM implementations and their applications in biomedical studies

    Photoacoustic brain imaging: from microscopic to macroscopic scales

    Get PDF
    Human brain mapping has become one of the most exciting contemporary research areas, with major breakthroughs expected in the coming decades. Modern brain imaging techniques have allowed neuroscientists to gather a wealth of anatomic and functional information about the brain. Among these techniques, by virtue of its rich optical absorption contrast, high spatial and temporal resolutions, and deep penetration, photoacoustic tomography (PAT) has attracted more and more attention, and is playing an increasingly important role in brain studies. In particular, PAT complements other brain imaging modalities by providing high-resolution functional and metabolic imaging. More importantly, PAT’s unique scalability enables scrutinizing the brain at both microscopic and macroscopic scales, using the same imaging contrast. In this review, we present the state-of-the-art PAT techniques for brain imaging, summarize representative neuroscience applications, outline the technical challenges in translating PAT to human brain imaging, and envision potential technological deliverables

    Breakthroughs in Photonics 2013: Photoacoustic Tomography in Biomedicine

    Get PDF
    Photoacoustic tomography (PAT) is one of the fastest growing biomedical imaging modalities in the last decade. Building on its high scalability and complementary imaging contrast to other mainstream modalities, PAT has gained substantial momentum in both preclinical and clinical studies. In 2013, PAT has grown markedly in both its technological capabilities and biomedical applications. In particular, breakthroughs have been made in super-resolution imaging, deep blood flow measurement, small animal resting state brain mapping, video rate functional human imaging, and human breast imaging. These breakthroughs have either successfully solved long-standing technical issues in PAT or significantly enhanced its imaging capability. This review will summarize state-of-the-art developments in PAT and highlight a few representative achievements of the year 2013

    Sensitivity of photoacoustic microscopy

    Get PDF
    Building on its high spatial resolution, deep penetration depth and excellent image contrast, 3D photoacoustic microscopy (PAM) has grown tremendously since its first publication in 2005. Integrating optical excitation and acoustic detection, PAM has broken through both the optical diffusion and optical diffraction limits. PAM has 100% relative sensitivity to optical absorption (i.e., a given percentage change in the optical absorption coefficient yields the same percentage change in the photoacoustic amplitude), and its ultimate detection sensitivity is limited only by thermal noise. Focusing on the engineering aspects of PAM, this Review discusses the detection sensitivity of PAM, compares the detection efficiency of different PAM designs, and summarizes the imaging performance of various endogenous and exogenous contrast agents. It then describes representative PAM applications with high detection sensitivity, and outlines paths to further improvement

    Photoacoustic tomography: fundamentals, advances and prospects

    Get PDF
    Optical microscopy has been contributing to the development of life science for more than three centuries. However, due to strong optical scattering in tissue, its in vivo imaging ability has been restricted to studies at superficial depths. Advances in photoacoustic tomography (PAT) now allow multiscale imaging at depths from sub-millimeter to several centimeters, with spatial resolutions from sub-micrometer to sub-millimeter. Because of this high scalability and its unique optical absorption contrast, PAT is capable of performing anatomical, functional, molecular and fluid-dynamic imaging at various system levels, and is playing an increasingly important role in fundamental biological research and clinical practice. This Review discusses recent technical progress in PAT and presents corresponding applications. It ends with a discussion of several prospects and their technical challenges

    Recent progress in photoacoustic molecular imaging

    Get PDF
    By acoustically detecting the optical absorption contrast, photoacoustic (PA) tomography (PAT) has broken the penetration limits of traditional high-resolution optical imaging. Through spectroscopic analysis of the target's optical absorption, PAT can identify a wealth of endogenous and exogenous molecules and thus is inherently capable of molecular imaging with high sensitivity. PAT's molecular sensitivity is uniquely accompanied by non-ionizing radiation, high spatial resolution, and deep penetration in biological tissues, which other optical imaging modalities cannot achieve yet. In this concise review, we summarize the most recent technological advancements in PA molecular imaging and highlight the novel molecular probes specifically made for PAT in deep tissues. We conclude with a brief discussion of the opportunities for future advancements
    • …
    corecore